Product

SCADA Suite

Plant supervision, from the field to the report.

A complete operating application. The hierarchy is navigable from site down to a single device and state propagates to the root: a fault in nitrification is visible from the top-level node without opening anything. The alarm bar stays at the bottom, with counts by priority and the current event readable from across the room.

SCADA Suite
SCADA Suite overall dashboard: plant hierarchy, sector filters, operating indicators, geographic map and alarm bar.
00 Overall dashboard: every plant on one screen, filtered by sector, with a geographic view.
SCADA Suite overall dashboard: plant hierarchy, sector filters, operating indicators, geographic map and alarm bar.

Overall dashboard: every plant on one screen, filtered by sector, with a geographic view.

01

Process mimics

Process screens carry P&ID symbols: shape says the device type, colour says its state, the animated line says where something is flowing. Every device opens its own faceplate with commands, interlocks and the reason it is held. Plant areas are navigable cards showing how many devices are running.

Process mimics
Wastewater plant mimic: process line from inlet pumping to discharge, with devices, values and area cards.
01 Process mimic with flow animation and per-device faceplates.
Wastewater plant mimic: process line from inlet pumping to discharge, with devices, values and area cards.

Process mimic with flow animation and per-device faceplates.

02

ISA-18.2 alarm management

Alarm priority is carried by colour, shape and text together, never by colour alone. The life cycle is complete: active unacknowledged, active acknowledged, cleared unacknowledged, shelved, suppressed. The system measures operator load per EEMUA 191 and flags when a burst exceeds ten alarms in ten minutes, the threshold beyond which nobody can keep up.

ISA-18.2 alarm management
Alarms page: unacknowledged count, priorities, flood detection and the ten most frequent alarms.
02 Alarms page with unacknowledged count, flood detection and a most-frequent ranking.
Alarms page: unacknowledged count, priorities, flood detection and the ten most frequent alarms.

Alarms page with unacknowledged count, flood detection and a most-frequent ranking.

03

Trends, archive and reporting

Years of history navigable while keeping the peaks through zoom, with alarm limits drawn on the chart and measurement cursors to read a value at a precise instant. The same series feed shift and production reports, exportable in the formats already used in the business.

Trends, archive and reporting
Trends page with alarm limits, measurement cursor and a table of minimum, average and maximum values.
03 Trends with limits, cursor and period statistics.
Trends page with alarm limits, measurement cursor and a table of minimum, average and maximum values.

Trends with limits, cursor and period statistics.

It connects to what is already there

It connects to what is already there

The system talks to the equipment you have, new or old: the PLC installed last month and the panel from the nineties sit on the same screen, because field protocols are covered natively and, where they are not enough, we build the connection ourselves. The data does not stay locked inside: it is read through REST APIs, secure WebSocket and MQTT, so ERP, MES and laboratory integrate with no manual exports and nobody in between. We handle the field too, from device selection to installation, and deliver a turnkey system. Then we keep it alive: continuous support, updates and version migrations over the years, with the platform growing alongside the plant and reaching into automation when needed.

Protocols covered by the platform

  • OPC UA
  • OPC DA
  • OPC A&E
  • OPC HDA
  • S7
  • S7Plus
  • Modbus/TCP
  • EtherNet/IP
  • IEC 60870-5
  • IEC 61850
  • DNP3
  • MQTT
  • SNMP
  • BACnet
  • SINAUT
  • RK512
  • S-Bus
  • SSI

SCADA compliance

SCADA compliance

Compliance is not a feature bolted on at the end: it is how the screen is drawn, how the alarm is classified and how the data is kept.

  • ISA-101.01

    High-performance interfaces

    Neutral backgrounds, colour reserved for abnormal states, four-level display hierarchy, control-room information density.

  • ISA-18.2 · IEC 62682

    Alarm management

    Full life cycle, redundant priority cues, shelving and suppression logged with reason and operator.

  • EEMUA 191

    Operator load

    Alarms measured per interval, flood detection, most-frequent ranking so the cause can be addressed.

  • ISA-5.1 · IEC 60073

    Symbols and colour

    Process symbols stay the P&ID ones; colour meaning is the prescribed one, not a graphic choice.

  • IEC 60204-1

    Commands

    Two-step confirmation on critical actions, interlocks that always state why they hold.

  • NIS2 · CRA

    Security and life cycle

    Separate environments, roles and action logging, software bill of materials and security updates across the system’s life.

These are product and process capabilities. They do not constitute certification issued by a third party.

Tell us about the plant.

Even just to find out whether the problem is in our field. You get a technical opinion back.

Write to us